Skip to main content

Remote Security Agent RSA 11 Wall Power Kit

Installation guide

Updated over 2 weeks ago

RSA 11 Wall Power Kit Diagram

RSA 11 Included Fasteners

RSA 11 System Schematic

Install Recommendations

Pole Mount

• Install the RSA IVR and camera modules at least 10 ft above ground level to reduce the risk of tampering.
• The total system weight is approximately 40 lb, plus any customer-provided wiring and conduit.
• Each module weighs no more than 20 lb, allowing for easier handling and installation.
• The installer must evaluate the pole, site conditions, and foundation to ensure they can support the required load and recommend reinforcement if needed.

Roof Mount

• The system weighs approximately 40 lb, plus any customer-provided wiring and conduit.
• Each module is under 20 lb, allowing for easy handling and installation.
• The installer must supply a ballast or anchoring solution suitable for the customer’s roof type and local weather or seismic conditions.
• In hot climates or on sun-exposed rooftops, adding a sun shade for the IVR module is recommended to help prevent overheating.

Wall Mount

  • Mount RSA IVR and camera modules at least 10 ft above ground to minimize tampering.

  • The system weighs approximately 40 lb, excluding customer-provided wiring and conduit.

  • Each module weighs no more than 20 lb for ease of handling and installation.

  • The installer must evaluate the customer’s structure to ensure adequate load-bearing capacity and recommend reinforcement if required.

STEP 01: OPEN IVR MODULE


Complete Steps 1–5 on the ground before mounting the module on the pole.

STEP 02: REMOVE POWER CONDUIT

  • Locate the power conduit on the left side of the IVR module and unplug the 2-pin power connector.

  • Unscrew the conduit nut and remove the power conduit.

  • Allow the black 4-pin data cable to slide out of the conduit and coil it inside the IVR module.

STEP 03: INSTALL AC POWER SUPPLY

  • Mount the AC power supply on the DIN rail at the bottom of the IVR module.

  • The AC power supply is included in the HW-RSA-11WKIT Wall Power Kit.

  • Snap the AC power supply into place on the DIN rail.

STEP 04: INSTALL AC POWER CONDUIT

  • Install the AC power conduit on the left side of the IVR module.

  • The conduit is included in the HW-RSA-11WKIT Wall Power Kit.

  • Ensure the 3-pin AC power connector is inside the IVR module.

  • Tighten the conduit nut to make the connection waterproof.

STEP 05: CONNECT AC POWER SUPPLY

  • Connect the 3-pin AC power connector between the AC power conduit and the AC power supply.

  • Connect the 2-pin DC power connector between the AC power supply and the 24V RSA terminal block.

  • Attach the ground ring to the M4 stud inside the enclosure using the provided M4 kep nut.

STEP 06A: ATTACH IVR MOUNTING FRAME TO STRUCTURE (POLE INSTALLS)

  • Temporarily secure the mounting frame to the pole using the provided large zip tie.

  • Permanently attach the frame using the four provided hose clamps.

  • Tighten hose clamps to 4 Nm (3 ft-lb) with a 7 mm socket.

  • Remove the temporary zip tie once the frame is secured.

STEP 06B: ATTACH IVR MOUNTING FRAME TO STRUCTURE (WALL/ROOF INSTALLS)

  • Secure the mounting frame to the structure at the indicated locations using the four provided masonry anchors or an alternative mounting system.

  • For the provided masonry anchors, drill a 3/8” pilot hole 3” deep and tighten anchors to 33 Nm (25 ft-lb) using a 9/16” socket.

STEP 07: INSTALL IVR MODULE

  • Mount the IVR module onto the IVR mounting frame.

  • Secure it using the four provided M8 × 20 bolts.

  • Tighten bolts to approximately 15 Nm (10 ft-lb) using the provided T40 Security Torx Allen key.

STEP 08: ATTACH HEAD UNIT TO STRUCTURE

For Pole Installs:

  • Attach the head unit mounting frame to the pole using the provided hose clamps.

  • Use a large zip tie if needed to hold the bracket in place during installation temporarily.

  • Tighten hose clamps to 4 Nm (3 ft-lb) with a 7 mm socket.

For Wall Installs:

  • Secure the head unit mounting frame to the structure using the four provided masonry anchors or an alternative mounting system.

  • For the provided masonry anchors, drill a 3/8” pilot hole 3” deep and tighten anchors to 33 Nm (25 ft-lb) with a 9/16” socket.

For All Installs:

  • Attach the head unit to the head unit mounting frame using the four provided M8 × 20 bolts.

  • Tighten bolts to approximately 15 Nm (10 ft-lb) using the provided T40 Torx Allen key.

STEP 09: CONNECT DATA CONDUIT

  • Install the data conduit fitting at the bottom of the head unit.

  • Plug the 6-pin connector from the conduit into the corresponding connector on the head unit.

  • Connect the four Ethernet cables from the conduit to the matching connectors on the cameras and speaker.

STEP 10: CONNECT AC POWER CONDUIT TO GRID POWER (120–220V AC)

  • Before installation, unplug the 3-pin AC power connector inside the IVR module.

  • Connect the hot, neutral, and ground wires of the AC power conduit to the 120V AC grid supply.

  • Reconnect the 3-pin AC power connector to power on the RSA system.

NOTE: The installer must provide a waterproof junction box with a knockout for 1” trade-size conduit (1 3/8” hole) and run the appropriate conduit to the main distribution panel.

Always follow safe practices and comply with all applicable local and national electrical codes.

STEP 11: CHECK CONNECTIONS

  • Connect the RSA system to power and wait about 30 seconds for the green lights to appear on the Ethernet connectors for the cameras and speaker inside the head unit.

  • Allow approximately 5 minutes for the RSA system to complete boot-up and connect to the cloud.

STEP 12: ADD DEVICE TO DASHBOARD

  • Make sure you are logged into the correct Spot Customer Dashboard. Contact your Spot Admin if you need access.

  • Locate the QR code label inside the IVR module.

  • Scan the QR code to add the RSA device to the dashboard. The serial number (SN) should populate automatically.

  • If the serial number does not populate, enter it manually. The SN can be found inside the IVR module.

STEP 13: CAMERA SETUP & VERIFICATION

  • Visually inspect each camera.

  • Adjust camera angles as needed to ensure optimal coverage.

STEP 14: TEST LIGHTS & BULLHORN

  • From the Spot Dashboard live view, activate the lights and confirm they are functioning correctly.

  • Play a test message to verify sound output from the speaker.

WARNING: The speaker is very loud. Ensure all personnel maintain a safe distance before testing

STEP 15: COIL AND MANAGE CONDUITS & CABLES

  • Neatly coil and organize all conduits and cables.

  • If possible, secure at least one bolt into the pole to prevent the unit from sliding due to wind or vibration.

  • Use the provided 300 mm (12 in) zip ties to coil and manage conduits and cables

Did this answer your question?